DESIGN, OPTIMIZATION AND VALIDATION OF CHEMOMETRIC ASSISTED SPECTROPHOTO-METRIC METHOD FOR SIMULTANEOUS DETERMINATION OF ESOMEPRAZOLE AND DOMPERIDONE IN COMBINED DOSAGE FORM
Rajavel, Ponnusamy 2 and Manojkumar, V 4 and Ramesh, Jayaprakash 1 and Prathap, Madeswaraguptha 3 DESIGN, OPTIMIZATION AND VALIDATION OF CHEMOMETRIC ASSISTED SPECTROPHOTO-METRIC METHOD FOR SIMULTANEOUS DETERMINATION OF ESOMEPRAZOLE AND DOMPERIDONE IN COMBINED DOSAGE FORM. DESIGN, OPTIMIZATION AND VALIDATION OF CHEMOMETRIC ASSISTED SPECTROPHOTO-METRIC METHOD FOR SIMULTANEOUS DETERMINATION OF ESOMEPRAZOLE AND DOMPERIDONE IN COMBINED DOSAGE FORM. ISSN 4212-4226
ESOMEPRAZOLE AND DOMPERIDONE.pdf - Published Version
Download (482kB)
Abstract
Abstract
Chemometric method – The response surface method was developed for simultaneous spectrophotometric estimation of Esomeprazole and Domperidone in pure form and its
pharmaceutical dosage form without any pre-treatment. In the present work, Esomeprazole and Domperidone were dissolved in ethanol and diluted to get a concentration of 10 µg / ml.
The solutions were scanned in the UV region in the wavelength range from 200 – 400 nm against ethanol as blank. From the spectrum, it was found that Esomeprazole and
Domperidone showed the maximum absorbance at 301nm and 290 nm respectively. Beer’s law was obeyed for the drugs in the concentration range of 4-24 µg/ml for Esomeprazole and
3-18 µg/ml for Domperidone. The correlation co-efficient value for the calibration graph was found to be 0.9997 and 0.9998 for Esomeprazole and Domperidone respectively, the
accuracy of the method was performed by recovery studies, and the average percentage recovery was found to be in the range of 99.76±0.7512 and 100.52±1.1023 for Esomeprazole
and Domperidone respectively. The amount of the drug recovered from the formulation was very close to the expected value and the % RSD value was found to be 0.7530 and 1.0966 for Esomeprazole and Domperidone respectively. The Percentage purity of Esomeprazole and Domperidone was found to be 100.25±1.0913 and 100.14±0.8103. The developed method was validated statistically by recovery studies as per ICH guidelines. Optical characteristics like slope, intercept, molar absorptivity, correlation coefficient, LOD, and LOQ were calculated. The % RSD value was found to be less than 2. Thus the proposed method was simple, precise, rapid, and accurate and can be successfully applied for routine quality control analysis of the simultaneous determination of Esomeprazole and Domperidone in bulk and a
combined tablet dosage form.
Keywords:
Chemometry, Central Composite design, UV Method Development, Validation
| Item Type: | Article |
|---|---|
| Subjects: | Ph Department of Pharmacy > Ph3 Pharmaceutical analysis |
| Divisions: | Faculty of Medicine, Health and Life Sciences > School of Pharmacy |
| Depositing User: | Unnamed user with email svcp@059 |
| Date Deposited: | 16 Oct 2026 07:53 |
| Last Modified: | 16 Oct 2026 07:53 |
| URI: | https://ir.svcop.ac.in/id/eprint/77 |